The wire is left over from a recent electrical range install. Authentic Southwire Romex Wire - 63 NM-B 55 Amps for indoor use only.
Southwire 125 Ft 6 3 Black Stranded Romex Simpull Cu Nm B W G Wire 63950002 The Home Depot Wire Conductors Electrical Supplies
3 PVC Insulation Thickness.
6/3 with ground romex. Type NM-B may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed. Wet locations on the other hand are a different story. The bare in NM cable Romex counts as ground but it is not insulated so it cant be used in the outside wiring.
Copper conductors are annealed soft copper. Im confused by the allowable ampacity stated under 33480 for NM. Location Cherry Valley NY Seattle WA.
6 AWG Number of Conductors. Allowable Ampacity for 6-3 WGRND NM-B Romex. 100 free shipping with savings of 10 or more over Amazon and eBay prices when ordering directly from our website.
076 mm 0029 inches Ground Wire Size. Soft bare copper solid per ASTM B3 and stranded per ASTM B3 and B8 Sheath. Of 6 AWG3 Wire with 10 AWG Ground Romex Copper Indoor Electrical Wire.
It can also be used for various building purposes both inside and outside the temperature should not exceed 90 C. Conductor insulation is 90C-rated polyvinyl chloride PVC nylon jacketed. WesBell Romex wire or NM-B cable is comprised of THHN wires and a PVC jacket.
UF-B is 50 more expensive and eats up all savings from XHHW for this job. 150 6-3 wground nm-b romex house wirecable 6 GAUGE 3 CONDUCTOR WGROUND - CONDUCTORS ARE BLACK WHITE RED WBARE GROUND We have no returns on cut wire unless there is a problem with the quality the cut of the wire or if we the seller makes a mistake then we will more than gladly accept a return. SlikQuik jacket allows for 50 percent reduction in pulling force for easier installation.
Up to 2 cash back Wire residential indoor branch circuits for outlets switches and other loads with Southwire Romex SIMpull type NM B Cable. I cant remember what rule allows you to run a separate ground wire. It states the allowable ampacity shall not exceed the 60 deg rating of 55 A but you can use the 90 deg C rating for ampacity adjustments as.
This job is for wiring a hot tub 220V 50amp. Ground wire from the 63 romex ran to the receptacle. Not sure but since the receptacle is grounded and its attached to the metal box that may be redundant grounding but I dont think its necessary.
Stranded conductors are compressed stranded. 013 mm 0005 inches. Can I use a 60 A breaker with 6 romex.
Its a nonmetallic sheathed cable used only indoors for wiring to appliances such as stoves and dryers throughout homes and buildings. Is it ok to use Romex and not UF-B. I was planning to use 63 Stranded Romex from the box through the attic through a block wall to the outside where it would be placed in SCH 80.
Apr 7 2021 14 LarryFine said. May be run in air voids of masonry block or tile walls not subject to excessive moisture and dampness. 30 mil color coded PVC sheath rated 90C is applied over the completed assembly.
10 AWG Nylon Thickness. 63 WGRND NM-B Romex. If this is insufficient then Ill buy some AWG 8 green THWN and just clip off the exposed ground on the 63.
SEU 3 wire romex without ground 2 wire with ground and 3 wire with ground but the ground either in parallel or cut off flush. Southwire Romex SIMpull 125-ft 63 Stranded Non-Metallic Wire By-the-Roll Item 57471 Model 63950002 Southwires Romex SIMpull type NM-B may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90ÂC. Romex Type NM-B Copper Building Wire is commonly applied in residential building wiring as a branch circuit for switches and outlets.
Southwire Romex R Brand SIMpull R NM-B cable is manufactured as 2 3 or 4 conductor cable with a bare ground wire. Browse our non-metallic sheathed cable inventory place your order today. Youre viewing six feet of 6 AWG 3 wire with 10 AWG Ground Copper Romex Indoor Electrical Wire rated up to 55 amps.
60ft inside 30ft outside. There is also an additional bare copper ground wire which can be slightly smaller than the rest of the insulated conductors. I could have used all pvc.
The egc on the dryer. We would run 63 SE aluminum for three wire ranges and 103 romex for three wire dryers.